Intelligent sensor system for the connection (M12-plug) to a universal-Ex-switching relay, stainless steel or stainless steel/Polymer-compound-material for highest corrosion resistance, room sensor for direct connection, other sensors by means of an M12-sensor cable (1m included, other lengths on request); in combination with universal-Ex-switching relay.
65-2661RK-10 M2A, IR Carbon Dioxide (CO2) 0-100%, sensor / transmitter, non explosion proof with j-box
61-1007RK-03 Sensor, IR, Carbon Dioxide (CO2) 0 - 5%, Non Explosion Proof with J-Box by RKI Instruments. When working on potentially hazardous jobsites, safety managers should look for workplace safety solutions that are dependable and steadfast.
OI-6000-X-X-X-X-O Sensor Assembly and OI-6000-IR-152-X-X-O Sensor Assembly Wire-Powered, Explosion-Proof Optional Radio & Relays. The OI-6000 is an explosion-proof ambient air fixed point remote gas sensor assembly with a wired power (3-wire), 12-25 VDC operating voltage, sensor assembly that can use Catalytic Bead, Electro-Chemical, PID, or Infrared sensor elements to detect …
NDIR SENSORS: NDIR – the most complete range of Infrared (IR) gas sensor on the market for CO2, SF6, hydrocarbon and refrigerant gases. We make no mystery about it: Non-Dispersive InfraRed (NDIR) technology is at the core of our DNA. This is completely designed and manufactured at the headquarters in Milan, Italy and our staff is constantly working to extend it, improve it and ...
EXPLOSION PROOF GAS SENSOR/TRANSMITTER S Series The RKI S series gas sensor/transmitters are highly reliable and cost effective basic 4-20 mA transmitters for the detection of common gas hazards. The S series transmitters are available for LEL (catalytic), LEL (IR) CH4, LEL (IR) HC, O2, H2S, CO, or CO2 (IR). The electronics are encased inside a potted package to avoid …
5100-28-IT Sensor. The 5100-28-IT Combustible Gas Sensor Module utilizes Infrared (IR) Combustible Gas Sensor to monitor for combustible gases (methane and others). Output Lower Explosive Limit (LEL) or % volume . Explosion proof, Class 1, Div. I, Groups C, D Class I, Zone 1Group IIC, IP66, IP65, NEMA 4X, T6 TA = - 40°C to 85 ° C II2 GD, Ex d ...
Infrarot(=IR)-Spektroskopie ein. Einen Überblick über die Thematik bietet Ihnen die Einführung ab Seite 3 dieser Anleitung. Der Theorieteil Ihres Versuchsprotokolls soll alle in dieser Liste hervorgehobenen Themen behandeln und alle gestellten Fragen beantworten. • Was ist das elektromagnetische Spektrum, und wie ist es gegliedert? Wo befindet sich der Infrarotbereich? • Studieren Sie d
65-2661RK-03 M2A, IR Carbon Dioxide (CO2) 0-5%, sensor / transmitter, non explosion proof with j-box Fixed - Station Gas Monitors << Back . M2A, IR Carbon Dioxide (CO2) 0-5%, sensor / transmitter, non explosion proof with j-box
OLCT 100 XP IR: Explosion-proof version and equipped with an infrared sensor for detection of CO2. OLCT 100 XP HT: High temperature explosion-proof version, for detection of explosive gases up to 200°C. Documentation. Commercial Brochures : Chinese - Dutch- English - French - German - Portuguese- Romanian - Serbian - Spanish - Swedish. User Manuals : Dutch- English - French - …
• OLCT 100 XP IR: Explosion-proof version with linear 4-20 mA output equipped with an infrared sensor for monitoring explosive gases, CO2 or some freons. • OLCT 100 XP HT: Explosion-proof high temperature version, for combustible gases detection up to 200 ° C, supplied with high temperature cables of 5, 10 or 15 meters. High SIL 2 reliability level The explosion-proof versions with ...
The infrared sensor provides explosive gas detection (methane, butane, propane, ethylene, hexane, etc.) in more severe environmental conditions, where the presence of poisons could harm the use of a catalytic cell. In addition to the LEL sensor range, the iTrans2 detector can also be configured with a 0-100% volume methane infrared sensor for bio-gas applications and CO2 infrared sensors ...
There is also an IR CO 2 sensor available in the range 0-2%Vol. The EC type transmitter is for use with the EC family of XCD sensors including Nitrogen Dioxide Carbon Monoxide (CO), Hydrogen Sulphide, (H 2 S), Nitrogen Dioxide (NO 2) and Hydrogen (H 2). The Oxygen transmitter is for use with the Oxygen (O 2) XCD sensors. A transmitter can auto-recognise any sensor from within its sensor family ...
Xgard IR is an explosion-proof gas detector which uses a dual-wavelength infrared sensor toprovide highly dependable detection of hazardous gases and vapours. Based on Crowcon’s hugely successful Xgard design, Xgard IR offers the many advantages of infrared sensor technology in a rugged and versatile package including; fail safe sensor …
61-1004RK-03 Sensor, IR, Carbon Dioxide (CO2) 0 - 5%, Explosion Proof with J-Box, UL Version by RKI Instruments. When working on potentially hazardous jobsites, safety managers should look for workplace safety solutions that are dependable and steadfast. When lives are on the line, a workplace cannot afford subpar safety products. That is why ...
Like every IR gas sensor, the analyzer at Mauna Loa used the same basic principle for measuring CO2. It has an infrared light radiation source at one end of a gas sample tube and an IR detector at the other. The band of infrared radiation is very close to the absorption band of CO2. As a result, the amount of light radiation that is absorbed by the CO2 molecules is proportional to the amount ...
The Xgard IR gas detector is a robust, explosion-proof gas sensor for hydrocarbons or carbon dioxide. The Xgard IR gas detector is available in different versions, depending on the gases for which it is to be used. The gas measuring device measures the respective gases with the help of an infrared sensor with dual wavelengths. The Xgard IR can easily be connected to existing measuring and ...
Xgard IR is an explosion-proof gas detector which uses a dual-wavelength infrared sensor toprovide highly dependable detection of hazardous gases and vapours. Based on Crowcon’s hugely successful Xgard design, Xgard IR offers the many advantages of infrared sensor technology in a rugged and versatile package including; fail safe sensor technology, immune to poisoning, no damage by over ...
The direct connect series are available for LEL, H2 Specific LEL, LEL IR, Oxygen, H2S, CO, CO2, and for a variety of toxic gases. The sensors for LEL, H2, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame arrestors, and approved for use in hazardous areas (Class 1, Div. 1 Groups B, C, D). An optional non-explosion proof version is available for oxygen, H2S, CO, and CO2 for ...
Dräger Sensor Infrarotsensor IR CO2 ES (Energy saving) -> 0 - 5 Vol.-% für X-am 5600 & 8000 ... DrägerSensoren - INFRAROT - Infrarotsensoren für explosive und brennbare Gase und/oder CO2. Produktbeschreibung "Alles was wir tun, tun wir mit Begeisterung - und wir tun es für das Leben!" Gefahr erkannt, Gefahr gebannt - Gase und Dämpfe sind fast immer gefährlich! Wenn Gase nicht in ...